What size generator do you need?

Tick what has to run at the same time. This adds up the running and starting watts from Honda's and Champion's charts and says which size of portable generator covers them. It's arithmetic, not a test.

Updated By the HoldBackup TeamHow we make these guides

This page has no store links. The pages it links to carry disclosed affiliate links.

Generator safety: carbon monoxide and backfeed

Carbon monoxide: never run a generator indoors, in a garage, basement or crawlspace, or near windows, doors or vents. Using a generator indoors can kill you in minutes. Use battery-powered carbon monoxide alarms in the home. CPSC Safety Alert 5123

Backfeed: never plug a generator into a wall outlet or a dryer outlet. That is extremely dangerous: it can energize utility lines and injure line workers and people in the home. Use a transfer switch or interlock installed by a licensed electrician. CPSC Safety Alert 5123 (PDF)

What has to run at the same time?

Food

Heating and cooling

Water

Laundry and kitchen

Network and small loads

Something else

How the starts add up

Honda's advice is to start loads with high starting watts at different times. Then only the largest start counts. Untick this if they might all start together.

Generac says a motor's starting watts are often two to three times its running watts.

Look for at least

Running watts
2,075 W
Starting watts
4,425 W

A mid-size portable generator covers it. The Westinghouse iGen5000DFc, for one, gives 3,900 W running and up to 5,000 W while a motor starts.

A furnace blower, central AC, well pump or water heater is wired into the house. It reaches a generator only through a transfer switch or interlock installed by a licensed electrician.

Westinghouse iGen5000DFc in our inverter generator picks. Next, read Dual Fuel Portable Generator: Propane or Gasoline in an Outage and Inverter Generator vs Conventional Portable Generator for Home Backup.

  1. Running: 400 + 875 + 800 = 2,075 W
  2. Starting: 2,075 W running + 2,350 W, the largest single start (Gas furnace blower, 1/2 hp) = 4,425 W

These are minimums, from the makers' charts, not a test. Your own appliance labels beat every preset here.

A hand working out sums in pencil on grid paper

How it's worked out

running W = every ticked load's running watts, added upstarting W = running W + the largest single startor, if loads may start together: running W + every start

The result above starts with a top-freezer fridge, a gas furnace blower and a sump pump: Running: 400 + 875 + 800 = 2,075 W. Starting: 2,075 W running + 2,350 W, the largest single start (Gas furnace blower, 1/2 hp) = 4,425 W.

Why only the largest start counts

A motor or compressor draws far more for two or three seconds as it starts. Generac's page on starting watts says to add up the running watts of everything you'll run at once and make sure the generator can also supply the highest single start. This page adds that start on top of the running total, which errs large. Honda's chart gives a load with no motor the same figure in both columns, so its starting figures may already include the running watts, and then the sum counts the starting load's running watts twice. Honda's power management page says to start big loads at different times, so only one start happens at once. A load with no motor, like a space heater, needs no extra starting watts: Champion's chart says to size those on running watts only.

Where the figures come from

Each preset is from Honda's wattage chart or Champion's, read on Nov 10, 2026. Where they differ, the preset is the higher figure, so the result errs large. Champion gives ranges; the preset is the top of the range. The kettle is from the runtime table.

The sizes come from generators we cover: the Honda EU2200i gives 1,800 W running and 2,200 W maximum, and the Westinghouse iGen5000DFc 3,900 W running and 5,000 W peak on gasoline. All of them have 120 V outlets only.

What it leaves out

If a medical device has to stay on, ask your medical provider and the device's maker what they recommend. This page isn't medical advice.

Sources

Every preset and where it comes from
  • Top-freezer fridge, 16 to 20 cu ft: 400 W running, 1,200 W starting. From Champion's chart and Honda's chart.
  • Bottom-freezer fridge, 25 to 29 cu ft: 400 W running, 1,200 W starting. From Champion's chart and Honda's chart.
  • Chest freezer: 500 W running, 1,200 W starting. From Champion's chart and Honda's chart.
  • Gas furnace blower, 1/2 hp: 875 W running, 2,350 W starting. From Honda's chart.
  • Window air conditioner, 10,000 BTU: 1,500 W running, 2,400 W starting. From Honda's chart and Champion's chart.
  • Central air conditioner, 3 ton: 3,500 W running, 6,000 W starting, 240 V. From Champion's chart.
  • Space heater: 1,500 W running, no extra starting watts. From Champion's chart.
  • Sump pump, 1/3 hp: 800 W running, 1,600 W starting. From Honda's chart and Champion's chart.
  • Well pump, 1/2 hp: 1,000 W running, 2,000 W starting, 240 V. From Champion's chart.
  • Electric water heater: 4,500 W running, no extra starting watts, 240 V. From Honda's chart and Champion's chart.
  • Washing machine: 1,200 W running, 2,300 W starting. From Honda's chart and Champion's chart.
  • Electric clothes dryer: 6,000 W running, 6,750 W starting, 240 V. From Champion's chart and Honda's chart.
  • Electric range, one burner: 2,400 W running, no extra starting watts, 240 V. From Champion's chart and Honda's chart.
  • Microwave, 1,000 W: 1,500 W running, no extra starting watts. From Honda's chart.
  • Coffee maker, 4 cup: 600 W running, no extra starting watts. From Honda's chart.
  • Electric kettle, while heating: 1,500 W running, no extra starting watts. From the runtime table.
  • Modem and Wi-Fi router: 20 W running, no extra starting watts. From Champion's chart.
  • Laptop: 250 W running, no extra starting watts. From Honda's chart.
  • TV, 32 to 55 inch: 400 W running, no extra starting watts. From Champion's chart.
  • LED lights, 10 bulbs: 150 W running, no extra starting watts. From Champion's chart.

For a battery instead of a generator, use the power station size calculator. For a UPS, use the UPS runtime calculator.