How long will a UPS run your devices?

Tick what has to stay on. This adds up the watts and reads each maker's runtime chart at that load. It's arithmetic, not a test.

Updated By the HoldBackup TeamHow we make these guides

This page has no store links. The pages it links to carry disclosed affiliate links.

What has to stay on?

Network

Computers

TV and games

Something else

A row with no figure is blank because we found none we could cite. Read the watts off the device's label, or measure them with a plug-in watt meter.

Limits

80% follows Schneider Electric's sizing advice for APC units, and this page applies it to every unit. Set it to 100 to use the maker's full rating.

VA is printed on some labels. If a label gives only volts and amps, multiply them. Leave the field empty if you don't have it, and the page checks watts only.

At this load

Your load
58 W

VA wasn't checked. The UPS sizing worksheet has room for both figures.

These are the makers' figures for a new battery, not a HoldBackup test. Runtime falls as the battery ages. See How to test UPS battery health before the next outage and When to replace a UPS battery in your battery backup.

A hand working out sums in pencil on grid paper

How it's worked out

load W = the watts of everything ticked, added upcarries it = load ≤ the UPS's watt rating × the share aboveruntime = the maker's figure at the next heavier load it publishes

The result above starts with a modem and Wi-Fi router and a 4-bay NAS: 58 W. Each maker publishes runtime at a set of loads. The page finds the first of those at or above yours and shows that figure.

Why it says "at least"

A UPS runs longer on a lighter load, so the maker's figure for the next heavier load is the shortest runtime its chart supports for yours. We don't estimate between two published figures, because the curve between them isn't a straight line. Under each answer you'll see the figures on either side, so you can judge for yourself.

"At least" compares your load with the maker's chart. It isn't a guarantee. Both makers say their figures are estimates for a new, fully charged battery in normal conditions.

Why there's no battery formula

Some calculators multiply battery volts by amp-hours and divide by watts. Runtime doesn't scale in a straight line with load, so that sum drifts from what the maker measured. How to Estimate Battery Backup (UPS) Runtime for Your Devices walks through reading one.

Watts and VA are separate limits

A UPS has a watt rating and a VA rating, and the load has to stay under both. This page checks watts from the figures above. It checks VA only if you enter a total from your device labels. UPS VA vs Watts: How to Read a Battery Backup (UPS) Rating explains the difference.

What it leaves out

  • Battery age. Every figure here is for a new battery. An older one runs for less.
  • Other models. Only units whose maker's chart we've read are listed. For any other UPS, read its own chart at your load.
  • Your own numbers. A plug-in watt meter beats every preset here.

If a medical device has to stay on, ask your medical provider and the device's maker what they recommend. This page isn't medical advice.

Sources

For hours instead of minutes, use the power station size calculator or the generator size calculator. To write a UPS plan down, use the UPS sizing worksheet.